AirSpeed 2900 gNB 5G OD Installation Guide
© Copyright Airspan Networks Ltd., 2021 P/N DUG01085 Rev. A, Nov 2021
9
- Poorly grounded tower/antenna sites that can conduct high lightning strike energy into equipment.
- Lack of properly installed lightning protection equipment that can cause equipment failures from
lightning induced currents.
A lighting protection system provides a means by which the energy may enter earth without passing
through and damaging parts of a structure. A lightning protection system does not prevent lightning
from striking; it provides a means for controlling it and preventing damage by providing a low
resistance path for the discharge of energy to travel safely to ground. Improperly grounded
connections are also a source of noise that can cause sensitive equipment to malfunction.
A good tower grounding system disperses most of the surge energy from a tower strike away from
the building and equipment.
To limit the equipment damage due to a lightning strike, the following practices are recommended
for the wireless system:
- Provide direct grounding from the antenna mounting bracket, the radio and antenna and the
lightning/surge protectors to the same ground point at the base of the tower or a ground bus on the
building. Use the grounding screws on the antenna bracket and the radio and antenna for terminating
the ground wires.
- The AC wall outlet ground must be connected to the same grounding system as the eNodeB.
Outdoor Ethernet Cabling
- Ethernet cable connected to should be outdoor grade with UV protection.
- Use shielded out CAT5e (minimum) cabled terminated with metallic RJ45 connectors.
- In order to protect any indoor units, install surge protection circuits on all copper cables on their
entrance to the building.
- Surge protection circuit must use a minimum 16AWG grounding cable.
DECLARATION OF CONFORMITY
Declaration of Conformity with Regard to the R&TTE Directive 2014/53/EU
Czech:
Airspan tímto prohlašuje, že tento přístroj je ve shodě se základními požadavky a dalšími příslušnými
ustanoveními směrnice 2014/53 / EU.
Danish:
Undertegnede, Airspan erkrer hermed, at følgende udstyrsenhed opfylder de væsentlige krav og
andre relevante krav i direktiv 2014/53 / EF.
Deutsch:
Hiermit erklärt Airspan, dass die Produkteinheit die grundlegenden Anforderungen und anderen
relevanten Bestimmungen der Richtlinie 2014/53 / EU erfüllt.
Estonian:
Käesolevaga kinnitab Airspan, et seadme seade vastab direktiivi 2014/53 / EL olulistele nõuetele ja
muudele kõnealuse direktiivi asjakohastele sätetele.
English:

Table of Contents

Related product manuals