2 Warning Information
3
You should be carefully read understand the contents of the instructions before operating
the equipment.
Operation should follow all warnings and cautions on the instrument
The power socket cable should be in accordance with the standard configuration and the
ground wire must be secure
Avoid opening the water heater switch without water supply.
Dentist unit tray shall not be stacked too heavy items (maximum load 2.5kg)
Dental unit pressure has been set before leaving factory, non-professionals are not free to
adjust.
Dental chair rotation limit has been locked, non-professionals are not free to adjust .
When get off work, you should turn off the main switch of water, gas, power .
The handpiece will supply water when the foot switch must be adjusted to the state of water
supply. (only for 4-way handpiece)
Unit or individual outpatient who use of the equipment must be equipped with or connected
to an amalgam separation device in the waste discharge system of dental unit.
The water and gas must be emptied and then cut off sources of water and electricity,
connect sources of water and electricity before the use.
3-way syringe handle and nozzle should be put into the disinfection bag to disinfect, and
then 134 (pressure 205.8KPa) high pressure steam disinfection, disinfection time is not
less than 3 minutes.
please read the user’s guide before cleaning and disinfecting the high speed handpiece and
low speed handpiece.
The cover are cleaned with wet cloth and neutral detergent to ensure smooth and elastic
leather surface and free from corrosion; PU parts and ABS parts are cleaned with a soft
cloth dampened with soap and water; the metal baking parts are washed with soft cloth
dipped in soapy water or wipe with a wax spray.
Take extra care with a fiber-optic handpiece to avoid damaging the shining part in the end
and make sure that the head will not come into contact with the treated mixture, keep a
certain distance or use a transparent sheet before the first 5 seconds of treatment.
P/N: 8013093 RevF
AJ16 User's Guide

Questions and Answers: