Page 62 of 68 
SELECTOR OUT, 
TB1, LEFT GND  Drain wire with gray 
 
SELECTOR OUT, 
TB2, RIGHT GND  Drain wire with gray 
 
IN TO OUTPUT 
TB3, RIGHT OUT  Red wire   
IN TO OUTPUT 
TB3, RIGHT GND  Drain wire with gray 
 
IN TO OUTPUT 
TB4, LEFT OUT  Black wire   
IN TO OUTPUT 
TB4, LEFT GND  Drain wire with gray 
 
Install the Tone Volume PCB: 
1.  Install the 1.75” tall standoffs (qty 2) that support the back edge of the Tone 
Volume PCB by screwing them into the threaded studs on the chassis. Don’t over-
tighten the standoffs or you will strip the fasteners out of the chassis. Note that the 
front two fasteners in the chassis are reserved for future options. 
2.  Remove and reserve the nuts and washers from the associated rotary controls on 
the Tone Volume PCB. 
3.  Dress the Tone Volume board power connections along the floor of the chassis, 
between the standoffs for the input selector board and the tone volume board.  
4.  Insert the potentiometer shafts fully through the front panel and fit the mounting 
holes at the back of the Tone Volume PCB over the screws in the 1.75” standoffs. 
You may have to slightly deflect the standoffs to line them up with the holes. 
5.  Fasten the board in place with 2 4-40x1/4” nuts. 
6.  Fasten the controls in place using the nuts and washers from step 2. The nuts have 
slightly different outside diameters. Use the larger outside diameter nuts with the 
balance and volume controls. 
Install the Op-amps into the sockets 
Install the 8-pin DIP ICs. Align the half-moon feature of the IC with the notch in the PCB 
silkscreen. If you need a reminder, see Figure 33. Double check the orientation before 
you install the op-amps. 
Designation  Value  Description  Done