6 — ONT management using an ONT interface
6-4 March 2011 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
ONT Product Information Guide Edition 01 3FE 54199 AAAA TCZZA
Supported utilities and ONTs
An ONT interface is accessible through a port on the ONT.
• HTTP interfaces are accessible through an Ethernet connection on indoor ONTs.
• The CLI interface is accessible through an Ethernet connection on indoor ONTs,
and a craft connection on outdoor ONTs.
• The CLI interface for Package C ONTs is accessible through an Ethernet
connection or craft connection on indoor and outdoor ONTs and MDUs.
• The butt set is used through a POTS connection on an indoor or outdoor ONT.
Table 6-2 identifies the utilities and the ONTs that these interfaces support.
Table 6-2 Supported utilities and ONTs
Utilities Supported
ONTs using
HTTP
interface
Supported
ONTs using CLI
interface
Supported
ONTs using
Package C
ONT HTTP
interface
Supported
ONTs using
Package C
ONT CLI
interface
Supported
ONTs using a
butt set
Retrieval of ONT product
information
Indoor ONTs
with Ethernet
connection
Indoor ONTs
with Ethernet
connection
Outdoor ONTs
with serial
RS-232 craft
interface
Indoor ONTs
with Ethernet
connection
Retrieval of ONT states
Retrieval of ONT uptime
Retrieval of RSSI
Retrieval of status of LEDs
Retrieval of ranging state
Retrieval of software
download state
ONT reset Indoor ONTs
with Ethernet
connection
OMCI and protocol tracing Indoor ONTs
with Ethernet
connection
Entry and clearing of SLID Indoor ONTs
with Ethernet
connection
Indoor and
outdoor ONTs
and MDUs with
Ethernet or
craft
connections
Indoor and
outdoor ONTS
with POTS
connection