6 — ONT management using an ONT interface
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a March 2011 6-13
3FE 54199 AAAA TCZZA Edition 01 ONT Product Information Guide
Procedures using CLI interface
The CLI interface is accessible in two ways:
craft port—The CLI interface is accessible through a craft port, which is provided
by some outdoor ONT models. You connect to the craft port with an RS-232
DB-9 connector, using a VT100 terminal or PC terminal emulation software set
at 9600 Baud, 8 bits, no parity.
Ethernet over LAN—The CLI interface is accessible through the first Ethernet
port on an indoor ONT using a computer or laptop with Telnet software.
The following procedures provide the steps to access and to disconnect from the CLI
interface using a craft port, or the first Ethernet port.
Procedure 6-3 To access the CLI interface using a craft port
1 Connect a laptop via serial cable to the RS-232 connector on the ONT.
2 Configure the communications software to the following settings:
bits/second = 9600
data bits = 8
parity = None (N)
stop bits = 1
terminal emulation = VT100
3 Log in to a craft session:
login:login
password:password
where
login is the username for the ONT
password is the password for the ONT
The Main menu appears.
4 STOP. This procedure is complete.
Procedure 6-4 To access the CLI interface using the first Ethernet
port
1 Connect a computer or laptop to the first Ethernet port on the ONT using an
Ethernet cable.
2 Configure the IP address on the laptop Ethernet port to 192.168.4.1.
Note — The CLI interface requires a specific username and password.
Contact your Alcatel-Lucent technical representative for login and
password information.