6 — ONT management using an ONT interface
6-16 March 2011 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
ONT Product Information Guide Edition 01 3FE 54199 AAAA TCZZA
Procedure 6-7 To access the CLI interface using a craft port
1 Connect a laptop via serial cable to the RS-232 connector on the ONT.
2 Configure the communications software to the following settings:
bits/second = 9600
data bits = 8
parity = None (N)
stop bits = 1
terminal emulation = VT100
3 Log in to a craft session:
<L>ogin
User Name:CRAFTSPERSON
Password:ALC#FGU
where
User Name is the username for the ONT
Password is the password for the ONT
The SLID menu appears.
4 STOP. This procedure is complete.
Procedure 6-8 To access the CLI interface using an Ethernet port
1 Connect a computer or laptop to an Ethernet port on the ONT using an Ethernet
cable.
2 Press the Reset button on the ONT. The ONT reboots with an enabled Telnet
server.
3 Start a Telnet session and Telnet to the ONT at 192.168.1.251.
4 Configure the IP address on the laptop Ethernet port to 192.168.1.x. For example,
192.168.1.100.