Managing Power over Ethernet (PoE) Monitoring Power over Ethernet via CLI
OmniSwitch 6250 Hardware Users Guide June 2012 page 5-11
Monitoring Power over Ethernet via CLI
To monitor current PoE statistics and settings, use the lanpower combo-port command. The command
output displays a list of all current PoE-capable, along with the following information for each port:
• Maximum power available to the port, in milliwatts
• Actual power used by the port
• Current port status
• Power priority status
• Power on/off status
Aggregate slot and chassis management information is also displayed. This information includes:
• Maximum watts available to the corresponding slot
• Amount of power budget remaining that can be available for PoE modules
• Total amount of power remaining that can be available for additional switch functions
When entering the show lanpower command, you must include a valid slot number in the command line
syntax. For example:
-> show lanpower 1
-> show lanpower 1
Port Maximum(mW) Actual Used(mW) Status Priority On/Off Class
----+-----------+---------------+-----------+---------+------+-------
1 31000 0 Undefined Low OFF None
2 31000 0 Undefined Low OFF None
3 31000 0 Undefined Low OFF None
4 31000 0 Undefined Low OFF None
Slot 1 Max Watts 225
1 Power Supplies Available
Note. For detailed information on show lanpower command output, refer to the OmniSwitch CLI Refer-
ence Guide.