Important Note. For management module redundancy to work effectively, the software on all switches
Secondary
Primary
Idle
Idle
Secondary
Offline
Idle
Idle
Primary
Offline
Secondary
Idle
!
Primary
Idle
Secondary
Idle
A stack of four OmniSwitch 6250 switches is operating
normally. The stack consists of a primary module, sec-
ondary module, and two elements operating in idle sta-
tus. (The software on all elements in the stack is
synchronized.)
The primary management module in the stack fails or is
taken offline (e.g., powered off or rebooted by the user).
The switch operating as the secondary management module
immediately takes over the primary role. Meanwhile, the
adjacent switch—previously operating in idle status—now
assumes the secondary management role.
If the switch that failed or was taken offline comes back
online, it will assume an idle role in the stack. In other
words, it will act essentially as an NI module in the virtual
chassis, passing traffic via its Ethernet.
1
2
3
4