EasyManua.ls Logo

aldes Dee Fly - Maintenance and Troubleshooting; Regular Maintenance Schedule; Troubleshooting Common Faults; Product Recycling and Guarantee

aldes Dee Fly
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RECYCLING
This product must not be thrown out with normal household waste.
At the end of its service life or when replaced it must be sent to a specialist collection
centre or back to a re-seller.
To the best of our knowledge, this article does not contain more than 0.1% by weight of
any substance requiring authorisation in compliance with the list of the 1st November 2008.
ALDES adheres to the ‘Eco-Systemes’ ecological organization www.ecosystemes.fr
Aldes has designed this product for easy recycling.
By participating in selective waste sorting, you are contributing to the recycling of this product and the protection
of our environment.
GUARANTEE
The unit is guaranteed for 2 years in accordance with our general terms and conditions of sale. The guarantee
takes effect from the date the product is purchased from the store with the invoice being proof of this date.
35
TROUBLESHOOTING
Faults Causes Actions
Steady red fault warning
light
Clogged filters Change the filters (see MAINTENANCE)
Blinking red fault light Motor failure
Change the faulty motor.
Contact your installer
Condensate leaks or water
noise in the heat exchanger
Poor condensate evacuation Make sure the water trap has been instal-
led properly (see INSTALLATION)
If necessary, unblock the condensate eva-
cuation duct
Low airflow levels at grilles Network leaks Inspect the aeraulic network and sealing
No auto-amplifier at the kit-
chen grille
Install the auto-amplifier behind the kit-
chen grille
Control panel Make sure the appropriate airflow rate has
been selected on the control panel,
depending on need (see PREPARATIONS
FOR INSTALLATION)
Cold incoming air supply By-pass open Make sure the by-pass is in good condition
and the motor is operating properly
The motors are not working Power supply Make sure the assembly is connected to
the mains
GB
MAINTENANCE
The Dee Fly HRV ventilation system can only remain efficient and provide its rated
capacity if it is regularly maintained.
Disconnect the electrical
supply before any
operations and ensure
that the unit cannot
be started
accidentally.
Never operate on the
electrical unit when
the unit is running
A LACK OF RESPECT FOR THESE SIMPLE RULES MAY LEAD TO:


 Total exclusion of the manufacturer's guarantee and thus you will be responsible for call-out charges and the replacement
of any defective equipment.
ONCE A YEAR
 During the 1st intervention, disconnect the motor from the power supply.
Remove the caps located on the cover. Place a screwdriver into the 2 holes and pierce
the covering. Restart the motor.
 Next, once a year, dust the fan-motor turbine wheel using a compressed air canister
(dry air). Fit the caps back onto the cover of the motor casing.
ONCE OR TWICE A YEAR
As indicated by the filter clogging warning
light on the control panel, change the heat
exchanger filters


 Replace the filters making sure they
are correctly positioned in the right
direction

 Re-initialise the control by pressing the
flow rate selection button for 5 seconds
until the red indicator light turns off.
ONCE OR TWICE A YEAR
Clean the exhaust grilles
34
Replacement filters for model with a by-pass (code 11023146)
Replacement filters for model without a by-pass (code 11023145)
ONCE OR TWICE A YEAR
Top up the water trap
(except for flat water trap)
1 2 3
4 5 6

Related product manuals