Do you have a question about the Allen-Bradley 1734-AENTR and is the answer not in the manual?
Product Type | EtherNet/IP Adapter |
---|---|
Series | POINT I/O |
Communication Protocol | Ethernet/IP |
Power Supply | 24V DC |
Shock | 30g |
Number of Ports | 1 |
Port Type | RJ45 |
Housing Material | Plastic |
Mounting Type | DIN Rail |
IP Rating | IP20 |
Network Address | Configurable via DHCP or Static IP |
Relative Humidity | 5…95% noncondensing |
Vibration | 5 g @ 10…500 Hz |
Enclosure | Open-style |
Identifies the intended audience for this user manual.
Lists other Rockwell publications for additional support.
Provides an overview of the adapters, their features, and usage.
Highlights crucial points to note before using the adapter.
Describes the connectivity and features of POINT I/O and ArmorPOINT I/O adapters.
Explains the process of configuring the chassis size for I/O connections.
Details the procedure and considerations for replacing an adapter.
Discusses rules and situations regarding empty terminal bases and module removal.
Describes the initial power-up sequence and module addressing.
Lists the key features and capabilities of the adapters.
Outlines the compatible firmware revisions and software releases.
Explains the primary tasks performed by the I/O adapters.
Details the use of the Common Industrial Protocol (CIP) for EtherNet/IP.
Explains the producer/consumer networking model used in CIP.
Describes how to specify the update rate (RPI) for data on the network.
Explains the support for rack-optimized and direct I/O connections.
Discusses the ability to mix rack-optimized and direct connection formats.
Describes how to physically install the I/O adapters and connect to the network.
Guides users to identify the external features of the I/O adapters.
Provides procedures for mounting the I/O adapters on a new system.
Details how to mount the POINT I/O adapter onto a DIN rail.
Explains how to mount the ArmorPOINT I/O adapter on a wall or panel.
Provides drilling dimensions for mounting the ArmorPOINT I/O adapter.
Steps for installing the mounting base for the ArmorPOINT I/O adapter.
Instructions for installing the POINT I/O adapter module on the DIN rail.
Instructions for installing the ArmorPOINT I/O adapter module.
Illustrates how to wire the POINT I/O adapter.
Guides on wiring the EtherNet/IP and auxiliary power connectors.
Outlines configuration requirements and procedures for IP address, subnet mask, and gateway.
Details IP address, subnet mask, and gateway address configuration needs.
Explains IP address structure, classes, and formatting.
Describes the gateway address and its role in multi-network systems.
Explains the subnet mask's function in splitting IP networks into subgroups.
Details how to set the network address using thumbwheel switches or DHCP.
Specific instructions for setting the network address on POINT I/O adapters.
Specific instructions for setting the network address on ArmorPOINT I/O adapters.
Guides on using the Rockwell BootP/DHCP utility for configuration.
Explains how to save the relation list from the BootP/DHCP utility.
Details using DHCP software for adapter configuration.
Guides on configuring the adapter for direct connection using RSLogix 5000.
Describes setting up the hardware for the example application.
Steps to create an example application in RSLogix 5000 software.
Procedures to add I/O modules to the controller's I/O configuration.
Steps to add the EtherNet/IP bridge to the I/O configuration.
Instructions to add the POINT I/O adapter to the I/O configuration.
Explains the different connection choices available for modules.
Steps to add POINT I/O modules to the I/O configuration list.
Steps to add a relay output module to the I/O configuration.
Steps to add a digital output module to the I/O configuration.
How to edit controller tags for use in the application program.
Steps to create a ladder program to test the I/O.
Procedure to download the created program to the controller.
How to verify and synchronize the module chassis size.
Steps to configure the adapter with a fixed IP address to ensure communication.
Discusses how to handle an overloaded adapter scenario.
Guides on configuring the adapter for direct and rack-optimized connections.
Describes setting up the I/O hardware for the example.
Steps to create an example application in RSLogix 5000 software.
Procedures to add I/O modules to the controller's I/O configuration.
Steps to add the EtherNet/IP bridge to the I/O configuration.
Instructions to add the I/O adapter as a child of the EtherNet/IP bridge.
Details on setting connection, chassis size, keying, and revision.
Steps to add and configure a POINT I/O module for rack-optimized connection.
Steps to add and configure a POINT I/O module for direct connection.
Procedure to download the program to the controller.
How to verify and synchronize the module chassis size.
Information on the meaning of LED status indicators.
Explains the status indicators for the 1734-AENTR adapter.
Explains the status indicators for the 1738-AENTR adapter.
Details general specifications for the POINT and ArmorPOINT I/O adapters.
Lists specifications for the POINT I/O 2 Port EtherNet/IP Adapter 1734-AENTR.
Lists specifications for the ArmorPOINT I/O 2 Port EtherNet/IP Adapter 1738-AENTR.
Details temperature, humidity, vibration, and other environmental specifications.
Lists the certifications and compliance standards for the adapters.
Explains how to access and use the adapter's web-based diagnostics.
Guides on using the adapter diagnostics home page and viewing information.
Instructions for accessing and using various diagnostic web pages.
How to use the Diagnostic Overview page for general diagnostics.
Guides on using the Network Settings page for network information.
How to use the Ethernet Statistics page for interface and media counters.
Explains how to use the I/O Connections page for CIP I/O information.
How to use the Diagnostic Messaging page for explicit message services.
Guides on working with configuration pages and their parameters.
How to use the Identity page for host name, description, and location entries.
Guides on configuring network settings like DHCP and TCP/IP parameters.
How to change passwords and manage the web server service.
Guides on browsing the chassis and viewing modules.
Explains the need to configure RSLinx drivers for communication.
Steps to install the RSLinx software on a computer.
Steps to configure the AB_ETH Ethernet communication driver.
Steps to configure the AB-ETH/IP Ethernet communication driver.