EasyManua.ls Logo

Allen-Bradley CENTERLINE 2100 - Page 34

Allen-Bradley CENTERLINE 2100
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34 Rockwell Automation Publication 2100-IN012G-EN-P - August 2016
Chapter 2 Installation Procedures
Figure 18 - Mounting Dimensions for 15 in. and 20 in. Deep Corner Section
[90 in. (2866 mm) high]
The optional external mounting channels add 1.5 in. (38.1 mm) to the height.
Dimension,
approx.
Section Depth
15 in. (381 mm) Deep
in. (mm)
20 in.(635 mm) Deep
in. (mm)
A 25.13 (638) 30.13 (765)
B 12.63 (321) 15.13 (384)
C 16.81 (427) 21.81 (554)
D 17.62 (448) 22.62 (575)
B
A
A
B
D
C
D
C
0.25 in. (6 mm)
0.25 in. (6 mm)
1.41 in. (36 mm)
1.41 in. (36 mm)
(2) Mounting Holes
0.63 in. (16 mm) Diameter
Ground Bus
(2) Mounting Slots
0.56 in. x 1.13 in. in Slots
(14 mm x 29 mm) Slots

Table of Contents

Related product manuals