Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 293
Troubleshoot the Kinetix 5700 Drive System Chapter 7
Table 145 - Drive Behavior, FLT Mxx Fault Codes
Exception Fault Code Exception Text
Inverter
Modules
2198-xxxx
Permanent
Magnet
Motor
Induction
Motor
Fault Action
Best Available
Stopping Action
(applies to major faults)
Ignore
Alarm
Minor Fault
Major Fault
FLT M02 – MOTOR VOLTAGE
(1)
Motor Voltage Mismatch Fault -ERSx X X XXXXDisable/Coast
FLT M07 – FEEDBACK INCREMENTAL
COUNT ERROR FAULT
Feedback Incremental Count Error
Fault
-ERSx X X XXXXDisable/Coast
FLT M26 – RUNTIME ERROR Runtime Error -ERSx X X –––XDisable/Coast
FLT M28 – SAFETY COMM
(2)
Safety Module Communication Error -ERSx X X –––XDisable/Coast
(1) Does not apply to induction motors in frequency control mode.
(2) Applies to drives in Integrated STO mode.
Table 146 - Drive Behavior, NODE FLT Fault Codes
Exception Fault Code Exception Text
Inverter
Modules
2198-xxxx
Permanent
Magnet Motor
Induction
Motor
Fault Action
Best Available
Stopping Action
(applies to major faults)
Ignore
Alarm
Minor Fault
Major Fault
NODE FLT 01 – LATE CTRL UPDATE Control Connection Update Fault
-ERS3 (series A)
XX
–––
X
Decel/Disable
-ERS4
-ERS3 (series B)
––– Ramped Decel
(1)
/Disable
NODE FLT 02 – PROC WATCHDOG Processor Watchdog Fault -ERSx X X –––XDisable/Coast
NODE FLT 03 – HARDWARE Hardware Fault -ERSx X X –––XDisable/Coast
NODE FLT 05 – CLOCK SKEW FLT Clock Skew Fault
-ERS3 (series A)
XX
–––
X
Decel/Disable
-ERS4
-ERS3 (series B)
––– Ramped Decel
(1)
/Disable
NODE FLT 06 – LOST CTRL CONN Lost Controller Connection Fault
-ERS3 (series A)
XX
–––
X
Decel/Disable
-ERS4
-ERS3 (series B)
–––
Programmable per
(2)
Connection Loss Stopping
Action (see Tab le 14 3 on
page 289
).
NODE FLT 07 – CLOCK SYNC Clock Sync Fault
-ERS3 (series A)
XX
–––
X
Decel/Disable
-ERS4
-ERS3 (series B)
––– Ramped Decel
(1)
/Disable
NODE FLT 09 – DUPLICATE IP ADDRESS Duplicate IP Address Fault -ERSx X X –––XDisable/Coast
(1) Available only in Velocity Control mode. Available stopping action is Current Decel in Position Control mode.
(2) With firmware revision 9.xxx. Do not change the default stopping action.