The TÜV Rheinland group has approved the 2198-Dxxx-ERSx and
2198-Sxxx-ERSx inverters with hardwired and integrated safe torque-off for
use in safety-related applications up to ISO 13849-1 Performance Level e
(PL e), SIL CL 3 per IEC 61508, IEC 61800-5-2, and IEC 62061, in which
removing the motion producing power is considered to be the safe state.
For product certifications currently available from Rockwell Automation, go to
https://www.rockwellautomation.com/global/certification/overview.page
.
Important Safety Considerations
The system user is responsible for the following:
Validation of any sensors or actuators connected to the system
Completing a machine-level risk assessment
Certification of the machine to the desired ISO 13849 performance
level or IEC 62061 SIL level
Project management and proof testing in accordance with ISO 13849
Stop Category Definition
Stop Category 0 as defined in IEC 60204 or safe torque-off as defined by
IEC 61800-5-2 is achieved with immediate removal of motion producing
power to the actuator.
Performance Level (PL) and Safety Integrity Level (SIL)
For safety-related control systems, Performance Level (PL), according to
ISO 13849-1, and SIL levels, according to IEC 61508 and IEC 62061, include
a rating of the systems ability to perform its safety functions. All of the safety-
related components of the control system must be included in both a risk
assessment and the determination of the achieved levels.
Refer to the ISO 13849-1, IEC 61508, and IEC 62061 standards for complete
information on requirements for PL and SIL determination.
IMPORTANT In the event of a malfunction, the most likely stop category is
Stop Category 0. When designing the machine application, timing and
distance must be considered for a coast to stop. For more information
regarding stop categories, refer to IEC 60204-1.