Rockwell Automation Publication 520-UM001A-EN-E - February 2013 125
Programming and Parameters Chapter 3
Fault and Diagnostic Group (continued)
F728 [EN Tx Packets]
A count of the number of transmitted packets reported by the embedded EtherNet/IP interface.
Values Default: Read Only
Min/Max: 0/65535
Display: 1
F729 [EN Tx Errors]
A count of the number of transmit errors reported by the embedded EtherNet/IP interface.
Values Default: Read Only
Min/Max: 0/65535
Display: 1
F730 [EN Missed IO Pkt]
The number of I/O packets missed.
Values Default: Read Only
Min/Max: 0/65535
Display: 1
F731 [DSI Errors]
The number of total DSI errors.
Values Default: Read Only
Min/Max: 0/65535
Display: 1

Table of Contents

Other manuals for Allen-Bradley PowerFlex 525

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 525 and is the answer not in the manual?

Allen-Bradley PowerFlex 525 Specifications

General IconGeneral
Horsepower0.5-30 HP
kW0.4-22 kW
Input Voltage200-240V AC, 380-480V AC
EnclosureIP20, NEMA/UL Type 1
CommunicationsEtherNet/IP
Control MethodsV/Hz, Sensorless Vector
STOSafe Torque Off (STO)
Output Voltage0-Input Voltage
Operating Temperature-20°C to 50°C (-4°F to 122°F)
Storage Temperature-40°C to 85°C (-40°F to 185°F)
Relative Humidity5-95% non-condensing
DimensionsVaries by model
WeightVaries by model

Related product manuals