Troubleshooting
13. Heating Element or Burner Shuts-Off Prematurely
Heating element or
burner shuts-off
prematurely
Is there
improper or
inadequate
exhaust and/or
make-up air?
Refer to
Installation
Manual
for exhaust and
make-up air
requirements.
Gas Models: Is
there insufficient
gas supply?
Open partially
closed gas shut-off
valve or correct low
pressure.
Gas Models:
Is tumbler
not properly
equipped for type
of gas used?
Tumbler is
equipped
for type of gas
specified on serial
plate. If orifices are
different from that
specified on serial
plate, obtain and
install proper
orifices.
Gas Models:
Is burner flame
improperly
adjusted?
Refer to
Installation
Manual
for burner flame
adjustment.
Is high limit
thermostat
cycling off?
Refer to
Flowchart 14
.
Is there
broken, loose
or incorrect
wiring?
Refer to
wiring diagram
located inside
contactor box.
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
TMB2142S
Glow-Bar Ignition
Gas Models: Is sensor
contact closing?
Replace
sensor.
No
Yes