28. Igniter Does Not Glow – Johnson Controls Glow-Bar System
Igniter does not glow –
Johnson Controls
Glow-Bar System
Is 120 volts
present between
black wire and
ground on main
thermostat?
Is 120 volts
present between
red and white wires
of igniter bracket?
Yes
Check heat
circuit.
No
Replace
igniter.
No
TMB2155S
Is 120 volts
present between
each of the purple
wires of sensor and
ground?
Replace
sensor.
Yes
No