EasyManua.ls Logo

Alliance Laundry Systems DTB50CG - Floor Requirements; Layout and Venting Guidelines

Alliance Laundry Systems DTB50CG
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26 70410501
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
14. Heating Element or Burner Repeatedly Cycles Off On High Limit
Thermostat
Heating element or
burner repeatedly
cycles off on high
limit thermostat
Is external
exhaust system
longer than
recommended or is
there inadequate
make-up air?
Refer to
Installation
Manual
for
exhaust and
make-up air
requirements.
Is lint screen
clogged?
Remove screen
and clean. Lint
screen and
compartment
should be cleaned
after every eight
hour shift.
Is there lint
in tumbler
ducts?
Clean tumbler
ducts.
Is there lint
in external
exhaust
system?
Disassemble
exhaust
system and
clean.
Is high limit
thermostat
cycling at too
low a
temperature?
Replace
thermostat.
Is lint door
panel not
closed
properly?
Remove lint door
panel, place lint
door panel back on
tumbler (ensuring a
tight fit).
TMB2143S
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes