70410501 45
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
31. Igniter Does Not Glow – White Rodgers Glow-Bar System
Igniter does not glow –
White Rodgers
Glow-Bar System
Is 80 - 120
volts present
between black wire
and ground on main
thermostat?
Is 80 - 120
volts present
between red and white
wires of igniter
bracket?
Yes
Check heat
circuit.
No
Replace
igniter.
Yes
TMB2158S
Is 80 - 120
volts present
between each of the
purple wires of
sensor and
ground?
No
Replace diode
logic board.
No

Table of Contents