Troubleshooting
18. Burners Not Burning Properly – Gas Models
Burner not burning
properly
Is there lint/dirt
in burner tube?
Is the gas
pressure too high
or low?
No
Disassemble
burner and
blow out the dirt.
Yes
Check serial
plate on back of
tumbler for
correct gas
pressure.
Yes
Is
the airflow
switch not
functioning
properly?
Yes
Replace airflow
switch.
TMB2147S
Does
the tumbler have
incorrect
orifices?
Yes
Tumbler is equipped
for the type of gas
specified on serial
plate. If orifices are
different from that
specified on serial
plate, obtain and
install correct
orifices.
Is the
exhaust duct
restricted or
blocked?
Yes
Disassemble
and clean
exhaust system.
No
No
No
Are burner air
shutters incorrectly
adjusted?
Refer to
Installation
Manual
for proper
flame adjustment.
Yes
No