Troubleshooting
35. OM Models: No Start With Cycle Selected, Start Button Pressed and Door
Closed (continued)
120 Volt/60 Hertz/1 Phase CG & CSH Nonreversing; 208-240 Volt/60 Hertz/1 or 3 Phase CSH
Nonreversing; 208-240 Volt/60 Hertz/3 Phase CE Nonreversing; 460-480 Volt/60 Hertz/3 Phase
CG, CE and CSH Nonreversing
TMB2162S-b
Is there
voltage to the
output of the
motor relay?
Replace
motor relay.
No
Unit
operational.
Continued from
previous page
Is there
voltage across
terminals 1 and 4
of the motor for
single phase units
or L1, L2 and L3
of three phase
units?
Correct wiring
between motor
and motor relay.
Does the
motor operate?
Replace motor.
Yes
No
Yes
No
Yes