114 801683
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer before servicing.
Never start the washer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
g. Open loading door, reach into inner basket and
rotate inner basket several times by hand.
Recheck belt alignment.
h. Pull down on motor to increase belt tension.
Use a Burroughs belt gauge to obtain proper
tension. Proper belt tension is obtained when
belt can be deflected approximately 1/4 inch
(6.35 mm) from normal position when
moderate pressure 50 to 60 pounds (22.68 to
27.22 Kg) is applied to a point midway between
pulleys. Refer to Figure 45.
i. After proper belt tension has been obtained,
tighten belt adjusting bolts firmly, then tighten
pivot bolts. Refer to Figure 45.
j. Reinstall lower front access panel. Refer to
Figure 25.
k. Lower cabinet top and install hold-down
screws.
l. Front Control Washers – Reinstall control
panel.
Rear Control Washers – Reinstall meter case,
front panel, door seal and dispenser drawer.

Table of Contents