Gas Conversion
NOTE: DO NOT connect the finisher to L.P. Gas
Service without converting the gas valve. An L.P.
Gas Conversion kit must be installed by the
Manufacturer’s Authorized Dealers, Distributors,
or qualified service personnel.
To convert the finisher to another type of gas, change
the orifice, adjust the air shutter, and install the
required gas conversion kit for the gas valve.
To change the orifice:
1. Remove the screws that hold the electrical
cabinet in position on the left side.
2. Swing the electrical cabinet open to access its
interior from the left.
3. Use a wrench to remove the main orifice. Refer
to Figure 9.
4. Insert a new orifice that meets the requirements
for the new type of gas.
To adjust the air shutter:
1. Refer to Table 5, Table 6 and Figure 10 to
determine the adjustment and flow rate.
2. Adjust the air shutter according to the
requirements for the new type of gas.
To install the gas conversion kit:
1. Make sure you have the correct conversion kit.
2. Follow the installation instructions that are
included with the kit.
NOTE: Instructions for installing gas conversion
kit can be found inside left frame of finisher.