Operation
1300003 (EN)
32
Thermal Warning Fan
When the thermal relay of the fan is activated, the
alarm sounds for one minute and display shows AL4.
The fan and heating are switched off and finisher
remains on. This alarm is usually caused by dirt on the
fan.
Alarm is automatically cancelled when the thermal
relay is closed or finisher is turned off.
Speed Regulator Alarm
When the speed regulator alarm is activated, the alarm
sounds for one minute and display shows AL5.
Finisher will automatically turn off. This fault
condition may be due to an overload of the cylinder
motor caused by a thick object inside the finisher or by
dirt in the cylinder motor.
Alarm is cancelled by restarting finisher or turning
finisher on and off.
No Flame (CE Gas Models Only)
When the burner is on or being ignited and a no flame
condition occurs, the alarm sounds for one minute and
display shows AL6.
The command for ignition remains active and the
finisher remains on.
When the gas device cancels the fault indication, the
alarm stops.
To try to re-ignite the burner, press the Decrease Preset
Temperature keypad and Increase Preset Temperature
keypad simultaneously after alarm stops.
If the reset fails, the alarm is activated again and one
of the following fault conditions occurs:
No gas supply. Check that the manual valve of
gas supply is open.
Gas pressure is insufficient or incorrect gas type
is being used (refer to Gas Connection section).
Ignition electrode is faulty. Replace ignition
electrode.
To cancel alarm without re-igniting burner, press Stop
keypad to stop finisher.
Overheating or Sensor Not Connected
If the temperature sensor is broken, not connected or if
sensor detects a temperature above 410°F (210°C)
continuously for two seconds, the alarm sounds for
one minute and display shows AL7. The finisher will
continue to operate.
Alarm can be cancelled by turning finisher off.
Extended Periods of Non-Use
Any time the finisher will not be used for more than a
week, the cylinder must be coated with a paraffin wax
layer to prevent corrosion. Refer to Maintenance
section for information on waxing the cylinder.