EasyManua.ls Logo

Alliance Laundry Systems UT025 - Time Dry and no Heat Modes

Alliance Laundry Systems UT025
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Programming the Electronic OPL Control
70381401
12
Time Dry and No Heat Modes
After temperature selection, press the TIME pad.
Refer to Figure 6.
Figure 6
A preset drying time, “Td:**”, will replace “A0:00” in
the display. This time can be changed by pressing the
MORE or LESS pad. For one minute changes, press
pad and release. For five minute changes, press pad
and hold. Maximum drying time allowed is 60
minutes. Refer to Table 3 for preset drying times.
Table 3
AC:**” will be displayed when tumbler is in Auto
Cool Down. Typical Cool Down times for fabric
selections are preset as shown in Table 2. The Cool
Down time can only be altered before cycle is started.
To alter Cool Down time, press the COOL DOWN pad
and then press the MORE or LESS pad (when Cool
Down time is altered, “TC:**” will be displayed). For
one minute changes, press pad and release. For
five minute changes, press pad and hold. Cooling time
can be from 1 to 39 minutes. To return to the Auto
Cool Down, press MORE or LESS pad until “AC:**
is displayed.
To start the cycle, press START. The total drying time
plus Cool Down time will display. During the cycle,
remaining time displays.
No Heat is a Time Dry cycle only. When NO HEAT is
pressed, a 20 minute preset time will display. This can
be changed from 1 minute to 60 minutes by pressing
the MORE or LESS pad before pressing START. The
COOL DOWN pad does not work in No Heat cycles.
T397I
Cycle Preset Time Range
HIGH 35 Min. 1 – 60 Min.
MEDIUM 20 Min. 1 – 60 Min.
MED LOW 15 Min. 1 – 60 Min.
LOW 30 Min. 1 – 60 Min.
NO HEAT 20 Min. 1 – 60 Min.
MORE
COOL
DOWN
LESS
TIME
+--
T397I
TIME DRY PADS