© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Programming the Electronic OPL Control
15
70381401
Temperature Sensor
To test the temperature sensor, hold COOL DOWN
pad and press the TEMP pad in the idle mode. This
will show the temperature detected by the control.
SH” displays and signal sounds if the temperature
sensor is shorted or sensor temperature is over 200°F
(93°C). Press the STOP/RESET pad twice within
three seconds and allow the tumbler to cool, then press
an ON/SELECT pad. If “SH” still displays, call for
service.
OP” displays and signal sounds three minutes after
the tumbler is started if the temperature sensor is faulty
or if a temperature below 24°F (-4.4°C) is detected. If
dryer temperature is above 24°F (-4.4°C), call for
service.
NOTE: To display the software revision level, hold
the AUTO pad and press the TIME pad while the
control is in idle mode.
Temperature Adjustment
Selecting a fabric type selects a preset ideal
temperature for that fabric. Lower temperatures may
be needed for small loads or when air flow through the
tumbler is less than ideal due to inadequate make-up
air or exhaust ducting.
Whenever the control is on, but not in No Heat, Cool
Down or Load Ready, pressing the TEMP pad displays
the three digits of the set temperature. Use the MORE
or LESS pad to increase or decrease the temperature.
Temperature Display (°F/°C)
To select between Fahrenheit and Celsius display, hold
in the TEMP DISPLAY pad while pressing the TEMP
pad.
NOTE: Temperature can be set from 80°F (27°C)
to 180°F (82°C) in the SPECIAL CYCLE and
SPECIAL TIME options only.
To include an adjusted temperature in a Custom cycle,
simply adjust temperature before pressing CUSTOM.
Cylinder Temperature Display
To see the approximate temperature at the exit of the
cylinder, press and hold the TEMP DISPLAY pad
(50 to 170 pound models only). For 0220, 0270 and
0350 models, the control program temperature for the
active cycle will be displayed when pressing TEMP
DISPLAY pad.