© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Programming the Electronic OPL Control
70381401
14
Special Cycle Mode
This allows the user to select the number of times the
tumbler will cycle from heat-on to heat-off. To enter
the Special Cycle Mode, press the SPECIAL CYCLE
pad after selecting a cycle. The display will read
“SC:**”. “**” is the number of times the tumbler will
cycle from heat-on to heat-off. This number can be
changed by pressing the MORE or LESS pad. For
increments of one, press pad and release. For
increments of five, press pad and hold for
three seconds. Range is from 1 to 99.
Press the START pad. The number shown after “SC:”
is the number of cycles selected. The number will
decrease as each cycle is completed. The default Cool
Down cycle for the Special Cycle Mode is Automatic
Cool Down.
NOTE: Since there are only 60 minutes of cycle
time, any cycles not completed within 60 minutes
will be skipped.
NOTE: Unlike the Time Dry Mode and Automatic
Mode, the regulating temperature in the Special
Cycle Mode has a range of 80°F (27°C) to 180°F
(82°C) or all heat cycles.
Special Time Mode
This mode is just like the Time Dry Mode, except that
the regulating temperature for each heat cycle ranges
from 80°F (27°C) to 180°F (82°C). To enter the
Special Time Mode, press the SPECIAL TIME pad
after selecting a cycle. The display will read “St:**”,
where “**” is the drying time. This time can be
changed by pressing the MORE or LESS pad. For
one minute changes, press the pad and release. For
five minute changes, press the pad and hold.
Maximum drying time allowed is 60 minutes.
“AC:**” will be displayed when tumbler is in Auto
Cool Down. Typical Cool Down times for fabric
selections are preset. The Cool Down time can only be
altered before cycle is started. To alter Cool Down
time press the COOL DOWN pad and then press the
MORE or LESS pad (when Cool Down time is altered,
“TC:**” will be displayed). For one minute changes,
press pad and release. For five minute changes, press
pad and hold. Cooling time can be from 1 to 39
minutes. To return to the Auto Cool Down, press
MORE or LESS pad until “AC:**” is displayed.
To start the cycle, press START. The total drying time
plus Cool Down time will display. During the cycle,
remaining time displays.
Security Lock-Out
The programming pads can be “locked-out” so
operators cannot change cycles on their own. When
lock-out is used, the operator can use only the factory-
set Automatic cycles and the one Custom cycle
allowed per SELECT pad. Before using lock-out,
create all desired Custom cycles.
To lock-out, hold SIGNAL pad and press MORE in
the idle mode.
To unlock, hold SIGNAL pad and press LESS in the
idle mode.
Show Mode
This mode will show all LEDs and light up entire
display while deactivating all pads. This mode allows
loading door to be opened and closed. To enter this
mode, the control must first be in the idle mode. Hold
the START pad and press the SAVE CUSTOM pad. To
exit Show Mode, hold the START pad and press the
SAVE CUSTOM pad.