Gas Models: Is
igniter inoperative?
Gas Models: Is
harness properly
connected to gas
valve coils?
No
Test igniter and
replace if
inoperative. Refer to
Test Procedures
section.
Yes
Gas Models: Is gas
flow in restricted in
gas orifice?
Yes
Check harness
connections to gas
valve coils, sensor
and main harness.
Reconnect as required.
No
Is thermistor
inoperative?
No
Clean out gas orifice.
Yes
Is wiring broken,
loose or incorrect?
No
Test thermistor and
replace if
inoperative. Refer to
Test Procedures
section.
Yes
Refer to wiring
diagram.