613-001727 Rev. D
iMG2400 Series
AT-iMG2426F
Installation Guide

Questions and Answers

  • S
    Shelly RichardsAug 7, 2025
    What to do if there is a problem with Allied Telesis Gateway telephone service?
    • D
      Danielle WeissAug 8, 2025
      If you're experiencing issues with your telephone service, try these steps: First, replace the existing cable with a cable that you know is working correctly. For POTS phones and fax machines, ensure the dial mode is set correctly as described in their respective manuals. Also, inspect the telephone or fax machine itself for any potential issues.
  • J
    Jamie Wilson Jr.Aug 13, 2025
    What to do if the VOIP LED is off on Allied Telesis Gateway?
    • M
      Michael HarrisAug 13, 2025
      If the VOIP LED doesn't light up when you lift the phone receiver, ensure the telephone cable is correctly connected, undamaged, and is the right type of cable. Try plugging a known good POTS telephone into the RJ-11 jack. If the VOIP LED lights up, the issue is likely with the original telephone cable. If it doesn't light up, there might be a problem with the iMG. In that case, verify the configuration, or reset the iMG to its factory defaults using the command sequence >system, >configure terminal, and then >boot config-file default.cfg. If problems persist after these steps, it is recommended to contact Allied Telesis.
  • S
    Sarah HardyAug 17, 2025
    How to fix Allied Telesis Gateway that is not operating correctly?
    • N
      Nicole PhelpsAug 17, 2025
      If the Gateway isn't working as expected, try resetting it. Disconnect the power cable, and then reconnect it.
  • L
    lawrencejasonAug 22, 2025
    What to do if the SYST LED is red on Allied Telesis Gateway?
    • U
      uloganAug 22, 2025
      If the SYST LED is red, unplug the power cable, wait 20 seconds, and then plug it back in. If the LED remains red, unplug the power cable and contact Allied Telesis.
  • J
    jwilliamsAug 27, 2025
    Why is the WAN LED off on my Allied Telesis Gateway?
    • S
      Stephanie PooleAug 27, 2025
      If the WAN LED is off, check the fiber optic port and connector on the pigtail to ensure they are clean. Also, verify that the connector is properly seated in the fiber optic port and that the fiber optic cable has an active light source.
  • J
    Jason FreemanSep 1, 2025
    How to troubleshoot Allied Telesis Gateway PWR LED being off?
    • A
      Anthony MartinezSep 1, 2025
      If the PWR LED is off, check the power cable to make sure it's undamaged and properly connected.

Summary

Electrical Safety and Emissions Standards

U.S. Federal Communications Commission

Details FCC compliance requirements and conditions for device operation.

Preface

Safety Precautions

Provides essential safety precautions to review before installing the gateway.

Chapter 2: Installing the Gateway

Outdoor Installation

Guides on the process of installing the gateway in an outdoor enclosure.

Indoor Installation

Provides instructions for installing the gateway in an indoor environment.

Chapter 3: Turn-Up and Troubleshooting

Turn-up Sequence

Details the step-by-step procedure for powering up and initializing the gateway.

Troubleshooting

Offers solutions to common problems encountered during gateway operation.

Allied Telesis AT-iMG2426F Specifications

General IconGeneral
Switching Capacity88 Gbps
Power SupplyInternal
Device TypeManaged
SFP+ Ports2
MAC Address Table Size16K entries
VLANs4094
Power Input100~240V AC, 50/60Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
MountingRack-mountable
Standards ComplianceIEEE 802.3 IEEE 802.3u IEEE 802.3ab IEEE 802.3z IEEE 802.3x IEEE 802.1D IEEE 802.1w IEEE 802.1s IEEE 802.1Q IEEE 802.1p
ManagementWeb-based GUI, CLI, SNMP