Translated from the original language - English - 37Manual 6-1624970M - rev. 1 - 11/01/2023
Customize the action mode of the STEP-BY-STEP function.
Normal: ("OPEN" - "STOP" - "CLOSE" - "STOP" - ...)
Classic operation of the STEP-BY-STEP mode. During handling, a STEP-BY-STEP control involves stopping the automation.
Alternate STOP: ("OPEN" - "STOP" - "CLOSE" - ...)
Alternating operation with STOP in opening. During opening handling, a STEP-BY-STEP control involves stopping the automation.
During the closing movement performs a reversal of motion.
Alternate: ("OPEN" - "CLOSE" - ...)
In this mode, the user does not have the possibility to stop the automation with a STEP-BY-STEP control, but instead a reversal is
obtained.
Condominium (Timer): ("OPEN" - ...)
The STEP-BY-STEP control allows only a complete opening of the automation. If the command persists with the automation in the
OPEN GATE position, it will wait for the release before starting the timing for automatic closing. Each press of the STEP-BY-STEP
control restores the countdown.
Condominium with immediate close: ("OPEN" - ...)
If the automation is not in the OPEN GATE position, the STEP-BY-STEP control allows a complete opening of the automation. When
the automation is in the OPEN GATE position, a STEP-BY-STEP command immediately closes the automation, resetting the automatic
closing timer if present.
PARAMETER VALUES DEFAULT
SbS
0 = Normal.
1 = Alternate STOP.
2 = Alternate.
3 = Condominium (timer).
4 = Condominium with immediate close.
0 = Normal
Behaviour after Black-out
Allows to automatically execute a closing command to reset the main supply voltage, following a Black-out. This movement is always
carried out at slow speed, until the "CLOSED GATE" position is reached.
PARAMETER VALUES DEFAULT
blt
OFF = No action performed.
ON = Automatically execute a "CLOSE" command.
OFF
Width of the slowdown area
Adjusts the width of the opening and closing slowdown area as a percentage of the total stroke length.
With the value "P" you can set custom areas during the learning of the races (see paragraph LEARNING WITH PERSONALIZED
SLOWDOWNS).
PARAMETER VALUES DEFAULT
LSi
From 5 to 100 % of the total stroke length.
P = Personalized areas.
10 %
Anti-skid function
It allows you to add extra working time compared to that stored during the course learning procedure, so as to ensure the complete
closure of the automation even if the working time learned is not enough to get to the position of "CLOSED GATE".
PARAMETER VALUES DEFAULT
ASL
OFF = disabled.
From 1 to 300 seconds.
15 seconds.