Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
CONFIDENTIAL PROPERTY OF GOODMAN MANUFACTURING COMPANY, L.P. OR ITS AFFILIATES NOT TO BE DISCLOSED TO
THERS, COPIED, OR USED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND,
ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF
GOODMAN MSP 860-01 WORKMANSHIP STANDARD.
LABEL, WIRING DIAGRAM
DATE: 03-31-22
ENG: NN
DWN BY: HT
DO NOT SCALE DRAWING
0140A00909
REV
CHK BY: VM
SHT 1 OF 2
GOODMAN MANUFACTURING COMPANY, L.P.
TOLERANCES UNLESS
OTHERWISE NOTED
ANGLES ± 1.5°
.X : ± .1
.XX : ± .03
.XXX : ± .015
HOLE Ø : ± .005
TUBE CUT LG: ± .063
DRAWING TO BE INTERPRETED IN
ACCORDANCE WITH ASME Y14.100
DIMENSIONS ARE IN INCHES
NLESS OTHERWISE NOTED
SPECIAL CHARACTERISTICS: (REFER MSP 822-01 FOR DETAILS)
=
SC
CC
ECN REV ZONE DESCRIPTION CHK DR DATE
2229028 INITIAL RELEASE HT 05-04-22
0140A00909-A
HEATER KIT
OUTPUT
4
3
6
59
8
7
10
11
12
BK
RD
BK
RD
BL
BR
WH
BL
RD
PU
YL
RD BK
GROUND LUG
(SEE NOTE 4)
24VAC
TB5
TB4
INSTALLING
AUX ALARM
(ALARM)
(SEE NOTE 9)
~
~
~
~
~
~
24VAC
COM COM
208
VAC
230
VAC
208
VAC
230
VAC
TR2
(SEE NOTE 1)
TR1
(SEE NOTE 1)
FAN
MOTOR
2
1
GY
BL
BK
RD
ECM MOTOR
BK
RD
PL1
PL2
9
7
8
45
6
3
2
1
PL3
PL4
INTEGRATED CONTROL:
POWER/HEATER
CONNECTOR
PL1, PL2
COMPONENT CODES:
TL
F1U, F2U
TR
THERMAL LIMIT
TRANSFORMER
FUSE LINK
NOTES:
1. PLACE RED WIRES ON 208 V TERMINAL OF
2-TRANSFORMER (TR1/TR2) FOR 208 VAC
OPERATION.
2. MANUFACTURER'S SPECIFIED REPLACEMENT
PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES AS
SUPPLIED WITH THIS UNIT MUST
BE REPLACED, IT MUST BE REPLACED
WITH WIRING MATERIAL HAVING A
TEMPERATURE RATING OF AT LEAST 105°C.
USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED
AND CONFORM TO N.E.C ANDLOCAL CODES.
5. TO RECALL THE LAST 6 FAULTS, MOST
RECENT TO LEAST RECENT, DEPRESS
FAULT RECALL BUTTON FOR MORE THAN 2
SECONDS WHILE IN STANDBY (NO THERMOSTAT
INPUTS)
6. RED STATUS LED PROVIDES NETWORK STATUS.
GREEN RX LED INDICATES NETWORK TRAFFIC.
USE LEARN BUTTON TO RESET NETWORK.
7. DISCARD CONNECTOR PL1 WHEN
INSTALLING OPTIONAL HEAT KIT.
8. THE POSITION OF SELECTOR SWITCHES
(DS1 - DS6) INDICATE FACTORY SETTING.
9. REMOVE SHORT RED CIRCUITING WIRE AND
PUT AUX ALARM SWITCH WHEN INSTALLING AUX
ALARM SWITCH.
10. USE N.E.C CLASS 2 WIRE
SELECTOR SWITCHDS1 - DS6
COLOR CODES:
BL - BLUE
RD - RED
YL - YELLOW
OR - ORANGE
BK - BLACK
GY - GREY
BR - BROWN
GR - GREEN
PU - PURPLE
WH - WHITE
LOW VOLTAGE
LOW VOLTAGE FIELD
HIGH VOLTAGE
HIGH VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
RESISTOR
OVERCURRENT
PROT. DEVICE
PLUG CONNECTION
EQUIPMENT GND
FIELD GROUND
DIP SWITCH(OFF)
FAULT RECALL
(SEE NOTE 5)
(SEE NOTE 6)
(SEE NOTE 6)
STATUS LED
X3A
X15A
BS2
X5A
X2A
BS1
SEG2
SEG1
DS1
DS2
X7A
X12A
X13A
RX LED
INDOOR UNIT
PCB
THERMIST OR
(HEAT EXCHANG ER 1,2)
MPU
CPU LED
EEV
M
K1R
K2R
LEARN
PS
TR1 TH1
TB2 TB1
CR2 1
F
L
A
S
H
W
R
IT
ER
R
AM
M
O
N
I
T
O
R
ON OFF
OR
GY
RD
YL
BK
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
X1A
TR2
TB3
F1U
TB4
TB5
TB7
COM
DS3
DS4
DS5
DS6
X3A
X15A
BS2
X5A
X2A
BS1
SEG2
SEG1
DS1
DS2
X7A
X12A
X13A
RX LED
X8A
INDOOR UNIT
PCB
THERMIST OR
(HEAT EXCHANG ER 1,2)
MPU
CPU LED
EEV
COIL
EEV
M
K1R
K2R
LEARN
PS
F2U
TR1 TH1
TB2 TB1
CR2 1
F
L
A
S
H
W
R
IT
ER
R
AM
M
O
N
I
T
O
R
ON OFF
INTEGRATION
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
X1A
TH2
TB10
TR2
TB3
F1U
TB4
TB5
TB8
ACC-OUT
TB7
DS3
DS4
DS5
DS6
AUX ALARM
(ALARM)
GR
AUX ALARM
(ALARM)
GR
RELAY IN
(ACC-OUT)
RELAY OUT
(ACC-IN)
(SEE NOTE 7)
GY
BK
THERMOSTAT
RD
BK
BK
RD
208/230
VAC
TO
HEATER KIT
(24 VAC)
TRANSFORMER
CONNECTOR
PL3, PL4
BL
TYPE
RD
ON OFF
READ THE INSTRUCTIONS
GR
RD
BL
PU
YL
RD
ACC-IN
TB6
K3R
PRESSURE
SENSOR
D
A
T
A
S
H
A
R
E
GRND
AIR
COM
1
208/230 VAC
CONDENSATE SWITCH
INDOOR
L1
HEAT 1 COIL/R1
TR2
INTEGRATED CONTROL MODULE
CIRCULATOR
+VDC (1)
GRND
BLWR
BLWR
X1A (2)
L2
40 VA
R
TO
MICRO
TH 2
CIRCULATOR
L1
INDOOR
GRND (4)
RX (2)
24 VAC
AIR
TB4
FUSE 3 A
GRND
TX (3)
X1A (1)
TB5
TRANSFORMER
DISCONNECT
HEAT 2 COIL/ R2
L2
X1A (3)
2
C
FIELD SPLICE
III
GRND
NOTES:
1. MATERIAL AS PER GOODMAN SPECIFICATION S4900061, TYPE A.
2. TEXT TO BE BLACK ON WHITE BACKGROUND.
3. BARCODE MUST ADHERE TO GOODMAN SPECIFICATION S4900070 (TWO DIMENSIONAL
ARCODE STANDARDS AND CHECK DIGIT ALGORITHM).
4. SUPPLIER PACKAGING MUST COMPLY WITH GOODMAN SPECIFICATION S4900110.
9.00 ±.10 LABEL
9.00 ±.10
LABEL
8.50 ±.10
FRAME
8.50 ±.10 FRAME
.25 TYP
.25TYP