17
4Operation
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Checking before use
Checking the condition of power distribution
Check the power distribution. When the power is turned ON, the
power lamp lights. If the external operation is in operation,
EXT.OPE lamp lights.When INSPECTION lamp lights, check the
error message of the message window and inspect and take
measures.
Starting and stopping the operation
Import
ant
Be sure to use the product only for collecting oil mist.
Do n
ot put alien substances to the exhaust port. Failure to do so could cause malfunction.
In case of occurring the cut powder, make sure to take measures such as installing the buf
fer plate for
preventin
g to put the cut powder into the prod
uct.
Make
sure to operate the product by the operation switch on the control panel or external operation, not
the main power.
Do not modify the product. Failure to do so could cause malfunction or the error of the display.
Adjust the temperature of the suction air to come in the range from 040
.
Adj
ust the environment temperature in the range from 040
.
Adj
ust the environment humidity in the range from 1090Rh. (No conden
sation)
Minimum ai
r volume in the case of “EM-15e” is 10m
3
/min , 20m
3
/min is the case of “EM-30e”.
The pro
duct is intended for collecting the oil mist with flash point of above 80 degree
s and over or the
solu
ble mist with less than 300 mS/m of specific electric conductivity. The machine cannot collect the oil
out of the cond
ition.
This produ
ct is for oil mist that has less than 200mg/m
3
of the maximum concentration. Otherwise,
Failure to do so could cause lack of performance such as frequent stopping the product or leaking the oil.
Do not operate without the charging electrode and the collecting electrode. It could cause malfunction
of
the infrast
ructure.
1 Starting operation
Press the ON switch.
The motor starts rotating and suctioning.
2 Stopping operation
Press the OFF switch.
The motor stops operation.
Check the lamp lighting.
POWER lamp
EXT.OPE lamp
INSPECTIO
N