5. Maintenance (continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Inspecting the charging electrode
Import
ant
The metallic side plates are very slippery due to oil on their surfaces. So, please be very careful not to cut
your finge
rs etc. on the edges at bends in
them.
T
o work with the collecting unit, use appropriate protective wear.(such as rubber gloves, protec
tive
glasse
s), and devices
.
Befo
re opening the inspection door or electrical equipment cover, turn off the power supply
to the mist
colle
ctor.
In order to operate the mist collector at the designed performance, install all collecting units correctly.
(such as eliminator and electrodes.)
Be sure to use Amano's genuine parts of collecting unit. The collecting unit for other model cannot
be
us
ed for this mist collector.
1 Opening the inspection door
Unscrew the hexagon bolt fixed inspection door and open the
inspection door.
2 Pulling out the charging electrode
Put your fingers on bends in each side plate and draw out the collecting
electrode.
When holding the charging electrode by the hand, do not put fingers
on the ground board. If the fingers go around on the board, the points
of the electrical discharging needle may stick the fingers.
Caution
Pull the collecting electrode gently.
Do not hold it in a manner that your finger(s) comes in the hole of the ground board.