EasyManua.ls Logo

AMAZON COMMERCIAL 6000 Count Compact - Duty Cycle, Continuity, Diode, and Temperature Specs

AMAZON COMMERCIAL 6000 Count Compact
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
EN
Duty cycle
Range
Resolution
Accuracy
0.1 to 99.9 % 0.1 % ±1.2 % f.m.*
±2digits
Pulse width: 100μs to 100ms
Frequency: 5Hz to 150kHz
Continuity
Measurement Output
Test current
max.0.35mA
Beeping tone when
resistance is less than
(50Ω)
Diode
Measurement Output
Test A is max.
0.9mA, open circuit
voltage max.3.2V
Forward voltage drop
ofdiode
Temperature
Range
Resolution
Accuracy***
-40°C to
+1000°C
1°C ±3 % f.m.* ±3°C
-40°F to
1832°F
1°F ±3 % f.m.* ±5°F
***Probe accuracy not included.
Sensor: Type-K Thermocouple;