Loading...
29
EN
Insert the black connector lead (N) into the
negative COM input jack (L).
Insert the red connector lead (N) into the
positive input jack (K).
Press the MODE button (D) twice to switch to
continuity check mode. (10) should light up
on the display(A).
Place the test probes (N) across the circuit or
part under test.
The stabilized value on the display (A) is read as
the actual reading.
If the resistance is less than approximately
50Ω, an audible signal is emitted.
If the circuit is open, OL lights up on the
display(A).
Capacitance measurement
NOTICE
To avoid electric shock or
measurement errors, discharge the capacitor
under test before measuring.
NOTICE
For best results, disconnect one side
of the capacitor under test. This is to avoid the
other components in the circuit to inhibiting the
measurement.