Mode Maximum Input
A~, A 10 A, 1000V fast acting
fuse (max. 30seconds
every 15minutes)
mA~, mA 800 mA, 1000V fast
acting fuse
V~, V 1000 V~ rms/
Frequency, Resistance,
Capacitance, Diode
Test, Continuity
250 V~ rms /
Surge Protection: 8 kV peak per IEC 61010
Do not measure current on a CAT III circuitry
whose voltage exceeds 1000 V.
Do not measure current on a CAT IV circuitry
whose voltage exceeds 600 V.
When measuring volts, do not switch to
current/resistance modes.
Set the function switch to the appropriate
position before measuring.
Set the function switch to the OFF position
when not in use.
When changing ranges always disconnect the
connector leads from the circuit under test.
Inspect the condition of the connector leads
and the product itself for any damage before
operation. Repair or replace any damage
before use.