BAG0083.2 11.17
7 Faults
7.1.1 Alarm messages
Alarm message Cause Remedy
A10 The spread rate cannot be main-
tained.
Reduce travel speed.
A11 No specified value (start of cali-
bration)
Start job and enter specified
value.
A12 No working width (start of calibra-
tion).
Enter working width
A13 The value from the spread width
sensor is incorrect.
Check cable.
Motor or sensor defective.
A14 The value from the spread rate
sensor is incorrect.
Check cable.
Motor or sensor defective.
A15 No calibration factor. Enter / determine calibration
factor.