Description of AMADOS+
9
AMADOS
+
DB 1001 01.04
3. Description of AMADOS
+
controls the spread rate [kg/ha] in dependence of th
e
forward speed. For this, the shutter slide positions can
be changed with the aid of 2 setting motors.
controls the spread rate in dependence of the of the
fertilizer data determined by weighing (only profiS-
broadcasters).
shows the actual hopper content
and determines the
applicated spread in [kg] rate after having carried out
the "start function" (only profiS-broadcasters).
allows the change of the spread rate in 10 %
steps (for both shutters simultaneously or indi-
vidually).
shows the current forward speed [k.p.h.].
determines the finished part area [ha].
stores the finished total area per season [ha].
AMADOS
+
has been equipped with a memory and a
battery. All entered and determined values are stored for
about 10 years even if the on-board power supply is
switched off. At the next switching on all data are avail-
able again.
3.1 Function description
Fig. 1
AMADOS
+
is supplied with a 6-digit display (Fig. 1
/1)
In operation position of the implement, the display
shows:
the current forward speed (Fig. 1/2) in [k.p.h.],
the current spread rate (Fig. 1/3) in [kg/ha] and
function control elements (Fig. 1
/4) as, e. g. left
and right hand shutter open.
On
the left hand edge of the display additionally 1
symbol is shown. The circle should flick during opera-
tion and indicates that the sensor for counting the
area or the travelled distance is transmitting impulses
to the.
During the spreading operation the pre-selected de-
sired spread rate can be changed for both shutters
simultaneously or individually.
The spread rate change for both shutters together
is controlled via the keys and
With
every single key pressure the pre-
selected spread
rate changes by + or – 10% for both shutters to-
gether.
The individual independent spread rate change for
the right hand and left hand shutter is controlled via
the keys , , and
. Every
single key pressure changes the pre-
selected spread
rate for the relevant shutter each by + or –
10%. The
percentile spread rate deviation from the pre-
selected
desired spread rate is shown in the display.