26
Malfunctions
AMADOS III-D DB 556 12.00
6.2 Fault messages
When using the AMADOS
+
on board-computer, the
following fault messages (error messages) may oc-
cur:
Fault
number /
error
Cause Remedy
10
rated value cannot be maintained.
- check rated value (see chapter 4.2.2).
- adapt speed.
- Switch off AMADOS
+
newly carry out the
start function (please refer to para. 4.3.1)
11
"spread rate" not entered.
- enter rated value (see chapter 4.2.2).
12
"working width" not entered.
- enter working width (see chapter 4.2.3).
13
no reaction by setting motor left hand side.
- check coding (see chapter 4.2.1).
- check setting motors for function, e. g. by
activating the function "emptying hopper"
(see chapter 4.4).
14
no reaction by setting motor right hand side.
- check coding (see chapter 4.2.1).
- check setting motors for function, e. g. by
activating the function "emptying hopper"
(see chapter 4.4).
16
The actual spread rate heavily deviates from
the dialled application rated value (e.g. due to
choked shutter opening).
- Remedy error source (e.g. clean shutter
opening). Then newly determine the cali-
bration factor.
no area
determina-
tion
“working width" not entered.
AMADOS
+
does not recognise "working posi-
tion"..
- enter working width (see chapter 4.2.3).
- check sensor "working position".
no speed
display
No impulses arrive at AMADOS III-D (Symbol
"speed impulse" does not light up).
The impulse value "Imp./100m" is missing.
- check sensor "X", cable ducting and wiring.
- enter impulse value or determine by driving
a test distance (see chapter 4.2.4).