OPTIONAL FEATURES EXPLAINED
OPTIONAL FEATURES EXPLAINED
Feature 06 – On/Off Status: The Luna Stat can be set to come
on or stay off when power is turned on to the thermostat.
Default is auto on/off from last power off.
Feature 07 – Temperature Calibration: The Luna Stat has the
option to adjust the sensor calibration by +/- 10
o
C in 0.5
o
C
increments. Default is 0
o
C.
Feature 08 – Switching Differential: The Luna Stat has the
option to changing the switching differential between 1 and 3
o
C.
Default is 1
o
C.
Feature 09 – Maximum Temperature: The Luna Stat has the
option to adjusting the maximum temperature set point. This
can be used as a limit on how high the heating is set to. This
range is from 2
o
C to 49.5
o
C. Default is 35
o
C.
Feature 10 – Minimum Temperature: The Luna Stat has the
option to adjusting the minimum temperature set point. This can
be used as a limit on how low the heating is set to. This range is
from 0
o
C to 47.5
o
C. Default is 5
o
C.
Feature 11 – Output Delay: The Luna Stat has the option to delay.