35
OPTIONAL FEATURES EXPLAINED
the switch output to prevent rapid switching on and off. This can
be set from 00 – 15 minutes. Default is 00.
Feature 12 – Optimum Start: The Luna Stat has the option to set
an optimum start of up to 3 hours, see page 18 for more detail.
Default is 0 hours.
Feature 13 – Rate of Change: For information only.
Feature 14 – Floor Temperature Limit: The Luna Stat has the
option to adjust the floor limit temperature used when a floor
sensor is installed and connected. This range is from 20
o
C to
60
o
C. Default is 28
o
C.
Feature 15 – Setback Enable: The Luna Stat has the option to be
programmed as a setback thermostat controlled from a separate
programmer. The programmer switched live should be
connected to the
terminal. Program mode (Feature 5) needs
to be set to 00 (non-programmable) to enable this feature.
Feature 16 – Setback Temperature: The Luna Stat has the option
to adjust the setback temperature from 3
o
C to 5
o
C. Default is 4
o
C.
OPTIONAL FEATURES EXPLAINED