Page/Seite 48 / 54 BG 65 dMove / BG 66 dMove Version 15-02-2023
6.9.1 Schaltplan für BG 65/66 dMove Motors
X
System aus funktionalen Gründen (EMV) erden.
6.9.1 Circuit Diagram for BG 65/66 dMove Motors
X
Earth the system for functional reasons (EMC).
Position/
Position
Fuse/
Sicherung
F1 B-type 16
F2 A-type 1
U+
from
power supply
from control unit (optional)
CB / Fuse and Resistor
Values see documentation
IN 1
IN 0
OUT 1
U Logic
hybrid
connector
AI +
OUT 2
IN 3
IN 2
N.C.
CAN L (only I/O version)
CAN H (only I/O version)
AI -
U Power
GND (common)
Ballast
(only CO version)
(only CO version)
Communication
OUT
Communication
IN
to next device (optional)
Wiring BG65 / 66 dMove drives
from logic / PLC
power supply
GND-
U+
example: connection
of a switch/sensor
example: signal
lamps/actors
GND-
connect housing to machine earth
for EMC shielding
F2
(!) Manual activation of the circuit breakers is only permitted if power-supplies are inactive
...to next motors
optional soft start circuit
see documentation
F1
M
~
-
GND
Ballast
U Power
BG65 / 66 dMove