EasyManua.ls Logo

Ametek dunkermotoren BG 65 dMove Series - Principle Circuit Diagram of Digital Inputs; Principle Circuit Diagram of Analogue Inputs; Principle Circuit Diagram of Digital Outputs; Prinzipschaltbild Digitaleingänge

Ametek dunkermotoren BG 65 dMove Series
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page/Seite 50 / 54 BG 65 dMove / BG 66 dMove Version 15-02-2023
6.11 Principle Circuit Diagram of Digital Inputs 6.11 Prinzipschaltbild Digitaleingänge
6.12 Principle Circuit Diagram of Analogue Inputs 6.12 Prinzipschaltbild Analogeingänge
6.13 Principle Circuit Diagram of Digital Outputs
6.13 Prinzipschaltbild Digitalausgänge
U
in
IN X
GND Logic
digital input, internal circuit
min low high max
U
in
[V]
[Ohms]
digital input
R
in
R
in
15.4k -3.0 <5.0 >15.0 33
18.9k -3.0 <2.5 >8.0 33
standard op�on
12V op�on
R
U
[V]
U
[V]
accuracy
linearity
analogue input
U
destruc�on
[V]
min max peak
22.0k
U
logic
-2V U
logic
0.500
R1
[Ohms]
U
out
[V] (acve)
digital output
connious
<= 0.250
I
out
[A] (acve)
OUT X
GND Logic
U Logic
digital output, internal circuit
R1
I
out
U
logic