AMETEK CTs NetWave
7. Technical data
7.1. 1-phase NetWave 3.x / 5 / 7.x
AC / DC Power source
NetWave 3 / 3.1 / 5 / 7 / 7.1 NetWave 7.2 / 7.3
Output voltage
0V 300 V AC (RMS) 0V 360 V AC (RMS)
0V - 425 V DC 0V - 500 V DC
Output frequency
DC 5 kHz
Frequency accuracy,
stability
100 ppm
NetWave
3
3.1
5
7 / 7.1 / 7-2 / 7.3
Output power AC
3.5 kVA
3 kVA
4.2 kVA
7-5 kVA
Output power DC
4.5 kW
4.25 kW
4.2 kW
9 kW
Output current
@ max. 300V AC
12 A
21 A
100 A
33 A
66 A
250 A
14 A
26 A
100 A
26 A
47 A
200 A
(RMS) continuous
(RMS) short (max. 3s)
repetitive peak
Output connector
Safety lab plugs ( 4mm banana)
Regulation
Voltage sense
internal or external, 4 wires
Sense range
Uset ≥ 100 V ac or dc: ± 5% of line setting
Distortion (THD)
Less than 0.5% (50 Hz / 60 Hz )
Output voltage
Stability
Better than 0.1%
Output voltage
Accuracy
Better than 0.5% FS
Output Noise
< 110 mVrms < 50 V < 320 mVrms
Max. compensable
drop on wires
5% of max. nominal voltage
Current limiter
accuracy
<5%
Current limiter steps
1A
Current limiter range
See chapter 0
Current Limiter Ranges
Protection
Over current
Over temperature
Over voltage mains supply
Low voltage mains supply
Waveform generator
Segment types DC
DC, Ramp, Square, Triangle, Sawtooth, Sine, Sine sweep, Sine ripple,
Exponent, Profile ...
Point signal DC
Segment types AC
Sine (flat curve, flat RMS adapted), Sine sweep, Sine up/down, Modulation,
Sine Dip, Sine unbalance, Sine step
Overswing, Sweep on Sine, Harmonic, Interharmonic, Interharmonic step,
Harmonic distortion ...
Segments with option Aircraft
Sine offset ( dc offset to sine), Sine Switching
Point Period AC
Sine, Triangle, Harmonic/Interharmonic, Harmonic Distortion
Segment duration
Unlimited
Data file import
CSV or Excel

Table of Contents