AMETEK CTs NetWave
Safety design
per IEC 1010, EN 61010
Power supply
3 x 400 V ± 10% (3P, N, PE)
3 x 208 V ± 10% (3P, N, PE) optional
line frequency
45 Hz 65 Hz
Input current max.
- NetWave 3
- NetWave 5
- NetWave 7
- NetWave 7-208
- NetWave 7-480
- NetWave 7.3
- NetWave 7.3-208
- NetWave 7.3-480
16 A 3-phase, N + PE (neutral max.27 A) @ 3 x 400 V
50 A with external matching transformer 3 x 208 V to 400 V
25 A with external matching transformer 3 x 480 V to 400 V
25 A 3-phase + PE @ 3 x 400 V
50 A 3-phase + PE @ 3 x 208 V
21 A 3-phase + PE @ 3 x 480 V
Fuses
Control F1 : 3.15 A slow blow (5 x 20 mm)
AC 3 x 400/480 V F2 : 25 A 500 V >120 kA (10 x 38 mm)
AC 3 x 208 V F2 : 50 A 500 V >120 kA (10 x 38 mm)
Input connector
CEE type 32 A
Terminal block 50 A
Noise (NW operates)
54dB A measured 1m in front of the device 1.5 m above ground
Dimension
Housing
19”, 9HU
Dimension (W x H x D)
449 mm x 420 mm x 504 mm
Weight
45 kg NetWave 3 / 5 / 7
231 kg NetWave 7.1 / 7.2 / 7.3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek NetWave 3.1 and is the answer not in the manual?

Ametek NetWave 3.1 Specifications

General IconGeneral
BrandAmetek
ModelNetWave 3.1
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals