17
Praca | EN
Operaon
NOTE!
Risk of overheang!
Exceeding the maximum permissible operang cycle can cause the
grinder to overheat.
– Do not exceed the maximum operang cycle
(see “Technical data” secon).
– Observe the recommended break when the maximum permissi-
ble operang cycle is reached (see “Technical data” secon).
• The grinder has a thermal overcurrent circuit-breaker which
interrupts the electric circuit of the grinder in case of electri-
cal overload.
To use the grinder again, rst set the On/O switch (5) to
switch posion 0 (o).
Then push the release buon (6) in.
You can now switch the grinder on by seng the On/O
switch to switch posion I and resume using the grinder (see
“Troubleshoong” secon).
• The grinder also has a motor protector, which switches o
the grinder when the motor becomes too hot.
As soon as the motor has cooled down, the grinder can be
put into operaon again (see “Troubleshoong” secon).
NOTE!
Risk of damage!
The operator cannot adjust the thermal overcurrent circuit-breaker. If
the circuit-breaker has been triggered several mes, a service partner
must be contacted for advice as the motor winding may be damaged.