CNC Setup Utility Manual
P/N 70000490C - Configuration Utilities
All rights reserved. Subject to change without notice.
10-December-04
4-2
Restore from Copy
Use this feature to restore a copy of the configuration from the A:-drive
(A:\P6MCFG.GFG) and save it as the new configuration file.
NOTE: If you restore your configuration file from a copy or a backup,
you will need to reboot when the system prompts you to do so.
You will be prompted for an automatic reboot.
1. See Map 2, Menu B. Highlight Restore from Copy. Press ENTER.
The system prompts for a password.
2. Type the limited access password. (Refer to Table 1-4, Default
Machine Passwords.) Press ENTER. Menu D displays.
3. Highlight A: to restore the configuration from a floppy diskette. The
configuration will be restored from A:\P6MCFG.CFG.
4. Highlight Other.. to restore the configuration from another drive or
another filename. Type in the drive from which you wish to restore the
configuration and the new filename (for example,
C:\HOME\FILE_1.CFG).
Restore from Backup
When the configuration is saved, the system creates a backup file
automatically. Use this feature to “swap” the backup file with the current
file.
See Map 2
, Menu B. Highlight Restore from Backup. Press ENTER.
The system automatically swaps the current file with the backup file.
Compare Configuration
Use this feature to determine if your current configuration file is the same
as another file, either on the A:-drive, or elsewhere.
1. See Map 2
, Menu B. Highlight Compare Configuration. Press
ENTER. Menu E displays.
2. Highlight A: to compare the current file with P6MCFG.CFG on the
A:-drive.
3. Highlight Other.. to compare the configuration with another drive and
another filename.. Type the directory with which you wish to compare
files. For example: C:\HOME\FILE_1.