3-4 Commands Command Directory
3-6 PN: 10370-10374 Rev. F MG369xC GPIB PM
AL0
Description: Sets the alternate frequency sweep RF output to L0.
Causes the preset (or previously set) L0 RF power level to be output during the alternate
frequency sweep. The command will also deselect any other previously programmed
alternate sweep power level. The command does not open the L0 power level parameter
for data entry. Use the parameter entry commands, XL0 or L0, to enter a new power
level.
Functional
Category: POWER LEVELING
Example: SSP; SF1; AF3; XL0 2 DB; AL0
Sets step sweep F1-F2, alternate step sweep F3-F4, and alternate level L0.
Related
Commands: L0, XL0
Front Panel Key: Frequency | Step Sweep | More > | Alternate Sweep > | Alternate Level > | L0
AL1
Description: Sets the alternate frequency sweep RF output to L1.
Causes the preset (or previously set) L1 RF power level to be output during the alternate
frequency sweep. The command will also deselect any other previously programmed
alternate sweep power level. The command does not open the L1 power level parameter
for data entry. Use the parameter entry commands, XL1 or L1, to enter a new power
level.
Functional
Category: POWER LEVELING
Example: SSP; SF1; AF3; XL1 2 DB; AL1
Sets step sweep F1-F2, alternate step sweep F3-F4, and alternate level L1.
Related
Commands: L1, XL1
Front Panel Key: Frequency | Step Sweep | More > | Alternate Sweep > | Alternate Level > | L1
AL2
Description: Sets the alternate frequency sweep RF output to L2.
Causes the preset (or previously set) L2 RF power level to be output during the
alternate frequency sweep. The command will also deselect any other previously
programmed alternate sweep power level. The command does not open the L2 power level
parameter for data entry. Use the parameter entry commands, XL2 or L2, to enter a new
power level.
Functional
Category: POWER LEVELING
Example: SSP; SF1; AF3; XL2 2 DB; AL2
Sets step sweep F1-F2, alternate step sweep F3-F4, and alternate level L2.
Related
Commands: L2, XL2
Front Panel Key: Frequency | Step Sweep | More > | Alternate Sweep > | Alternate Level > | L2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu MG369 C Series and is the answer not in the manual?

Anritsu MG369 C Series Specifications

General IconGeneral
BrandAnritsu
ModelMG369 C Series
CategoryPortable Generator
LanguageEnglish

Related product manuals