Command Directory 3-4 Commands
MG369xC GPIB PM PN: 10370-10374 Rev. F 3-35
F0 <value> <unit>
Description: Opens the F0 parameter.
Permits setting the F0 parameter. The frequency setting is determined by the frequency
range of the particular MG369xC model.
Functional
Category: PARAMETER ENTRY
Value: Frequency range of the MG369xC model
Units: GH, MH, KH, HZ
Output Command: OF0 returns the F0 frequency value (in MHz) to the controller.
Front Panel Key: Frequency | CW | Frequency Control > | F0 | Edit F0
F1 <value> <unit>
Description: Opens the F1 parameter.
Permits setting the F1 parameter. The frequency setting is determined by the frequency
range of the particular MG369xC model.
Functional
Category: PARAMETER ENTRY
Value: Frequency range of the MG369xC model
Units: GH, MH, KH, HZ
Front Panel Key: Frequency | CW | Edit F1
Output Command: OF1 returns the F1 frequency value (in MHz) to the controller.
F2 <value> <unit>
Description: Opens the F2 parameter.
Permits setting the F2 parameter. The frequency setting is determined by the frequency
range of the particular MG369xC model.
Functional
Category: PARAMETER ENTRY
Value: Frequency range of the MG369xC model
Units: GH, MH, KH, HZ
Output Command: OF2 returns the F2 frequency value (in MHz) to the controller.
Front Panel Key: Frequency | CW | Frequency Control > | F2 | Edit F2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu MG369 C Series and is the answer not in the manual?

Anritsu MG369 C Series Specifications

General IconGeneral
BrandAnritsu
ModelMG369 C Series
CategoryPortable Generator
LanguageEnglish

Related product manuals