92
Feeding voltage: 230 V Power 25 W Attachment type : E14
14.1.
MAINTENANCE PROGRAMME
Operators:
Qualified technician
EVERY MONTH: Check that all the electric parts are in good working order.
14.2.
FAULT REPAIR: ORDINARY AND SPECIALIZED REPAIRS
If a malfunction occurs, check chapter 14.5 to ascertain whether the damage requires specialized repair, or if
a little understanding and knowledge of the contents of this manual are sufficient.
REPLACEMENT OF A LIGHT BULB AND/OR DOOR GLASS
The baking chamber's light bulb is to be replaced from the inside of the baking chamber.
Wait for the oven to be at a temperature that is not dangerous, open the door of the oven and using a
screwdriver (or similar) prize off the glass covering the lamp on the oven wall
Hold the glass carefully maneuvering it in such a way that it does not get knocked and broken
Replace the lamp with a similar lamp paying attention not to touch the bulb with your fingers (it would burn
quickly), if necessary clean the bulb to cancel the grease marks left from your fingers.
Refit the protective glass and the joint paying attention not to fix screws too tight.
CLEANING THE STEAM GENERATOR
Cleaning frequency: at least every 4/6 months using water with a low chalk content while using
water that is harder eliminate the chalk deposits inside the boiler each week by inserting a
decalcifying liquid (liquid charge ) until the boiler is full; be careful to prevent any spillage on the
parts of the prover.
As liquid for removing chalk, common kitchen VINEGAR is recommended alternatively Citric Acid
(diluted to10%) or similar products found on the market (suitable for food processing machinery)
can be used.
Let the liquid act for around 24 hours, then empty the boiler opening the tap inside the prover
(discharge tap) and let the discharge liquid run off into a suitable receptacle.
Carry out at least three or four washing cycles with natural water to remove all the residues and
odors of the decalcifying liquid.
One or two daily drainages of at least two liters of water with the steam generator running
lengthens the washing frequency of washing with the decalcifying compound
The discharge liquids can be drained into the ordinary sewer system.
During normal working the green pilot light inside the prover is always on, it goes off it means that
the safety thermostat has cut in.
To reset the safety thermostat wait for the cooling and then press the red button protruding into
the prover.
The continuous intervention of the safety thermostat is due to the excessive chalk deposit inside
the boiler that then requires clearing with the decalcifying liquid.
NB) During the functioning the discharge tap must be closed