95
Stainless steel door with window and with downwards opening (Optional extra)
REPLACEMENT OF PARTS OF THE PROVER
REPLACING A CONTROL SWITCH
To replace a control switch, do the following operations:
• Remove the right-hand side panel of the prover.
• Disconnect the connectors of the switch.
• Push the switch out and replace it.
• Carry out the operations in reverse order to re-assemble.
REPLACING THE HYGRO-THERMOSTAT
To replace the hygro-thermostat, do the following operations:
Working from inside the prover the hygro-thermostat is on the left-hand inside wall
Replace the hygro-thermostat with a similar one.
Carry out the operations in reverse order to re-assemble.
REPLACING A HEATING ELEMENT OR THE FAN
To replace the heating element or the fan inside the prover on the right hand side do the following
operations:
Unscrew the fixing screws of the heating element's carter from its frame.
Remove the right-hand side panel of the prover.
Disconnect the power wires of the heating element or the fan.
Remove the heating element or the fan.
Carry out the operations in reverse order to re-assemble the new parts.
REPLACING THE STEAM GENERATOR (OPTIONAL)
The steam generator is a single part that cannot be broken up that includes the stainless-steel box, the
heating element and the operational as well as safety thermostat.
NB) it is not possible to supply the components separately.
To replace the steam generator, do the following operations:
Remove the right-hand side of the prover.
Disconnect the connection wires.
Disconnect the generator from the prover.
Replace the steam generator with a similar one
Carry out the operations in reverse order to re-assemble the new steam generator